Test and measurement
Multimeters and electrical testers in Saudi Arabia
Digital multimeters for everyday fault finding, clamp meters for current without breaking the circuit, insulation testers for cables and motors, earth testers for earthing systems and voltage testers for proving dead.
Digital multimeters
True-RMS meters for voltage, current, resistance, continuity, capacitance and frequency.
Clamp meters
AC and AC/DC current up to 1000 A or more without opening the circuit, many with flexible coils.
Insulation resistance testers
250 V to 5 kV and above for cables, motors, switchgear and transformers.
Earth testers
Fall-of-potential, clamp-on and loop testers for earthing systems and installations.
Hipot and high-voltage testers
AC and DC withstand (hipot) testers for cables, switchgear, motors and production lines.
- BAUR PGK 25 hipot tester PGK 25
- BAUR PGK 50 hipot tester PGK 50
- BAUR PGK 70 HB hipot tester PGK 70 HB
- BAUR PGK 70/2.5 HB hipot tester PGK 70/2.5 HB
- BAUR PGK 80 hipot tester PGK 80
- BAUR PGK 100 / 5 HB hipot tester PGK 100 / 5 HB
- BAUR PGK 100 HB hipot tester PGK 100 HB
- BAUR PGK 150 / 5 HB hipot tester PGK 150 / 5 HB
Micro-ohmmeters (DLRO)
10 A to 600 A low-resistance ohmmeters for breaker contacts, busbar joints and cable splices.
Battery testers
Internal-resistance and capacity testers for UPS, substation and telecom batteries.
Cable locators and tracers
Locators for buried cables and pipes, wire tracers and cable fault locators.
Insulating oil testers
Breakdown-voltage test sets for transformer and switchgear oil.
Voltage and socket testers
Two-pole testers and non-contact pens to prove a circuit is dead before work.
How to choose a meter or tester
Measurement category (CAT)
CAT III for distribution boards and fixed installation, CAT IV at the supply origin and outdoor lines. The category matters more than the voltage figure.
True RMS
Drives, LED drivers and UPS units distort the waveform; only a True-RMS meter reads current and voltage correctly there.
Insulation test voltage
500 V for low-voltage wiring, 1 kV for motors and 690 V systems, 2.5 to 5 kV for medium-voltage cables and machines.
Calibration
Ask for a calibration certificate when the meter is used for commissioning or for client reports.
Questions
Do the meters come with calibration certificates?
Most come with the maker's certificate; traceable calibration with a report can be quoted on request.
Which meter do I need for VFD and motor work?
A True-RMS meter with a low-pass filter for drive outputs, plus a 1 kV insulation tester for the motor windings.
Do you supply test leads, probes and spare fuses?
Yes. Test leads, clips, probes and the meter's own fuses can be on the same quotation.
Do you deliver multimeters and electrical testers outside Jeddah?
Yes. We supply from Jeddah to Riyadh, Dammam and Al Khobar, Jubail, Yanbu, Makkah and every other region; the delivery time is on the quotation.