PhotoPart numberDescriptionRated power AC-3 (400 V)UL/CSA general use (600 V)TerminalsBrand
1SAM201901R1001Aux.-contact for frontmounting -1SAM201901R1001 –———ABB
1SAM201903R1001SK1-11 Signal contact -1SAM201903R1001 –———ABB
1SAM250000R1005Manual motor starter -1SAM250000R1005 – (MS116-1.0)———ABB
1SAM250000R1006Manual motor starter -1SAM250000R1006 – (MS116-1.6)———ABB
1SAM250000R1007Manual motor starter -1SAM250000R1007 – (MS116-2.5)———ABB
1SAM250000R1008Manual motor starter -1SAM250000R1008 –———ABB
1SAM350000R1013Manual motor starter -1SAM350000R1013 –———ABB
MO132-0.4Manual motor starter MO132-0.4, 0.09 kW AC-3 / 0.40 100 A AC-10.09 kW5.00 AScrewABB
MO132-0.25Manual motor starter MO132-0.25, 0.06 kW AC-3 / 0.25 100 A AC-10.06 kW3.10 AScrewABB
MO132-0.63Manual motor starter MO132-0.63, 0.12 kW AC-3 / 0.63 100 A AC-10.12 kW7.90 AScrewABB
MO132-1.0Manual motor starter MO132-1.0, 0.25 kW AC-3 / 1.0 100 A AC-10.25 kW12.5 AScrewABB
MO132-1.6Manual motor starter MO132-1.6, 0.55 kW AC-3 / 1.6 100 A AC-10.55 kW20.0 AScrewABB
MO132-2.5Manual motor starter MO132-2.5, 0.75 kW AC-3 / 2.5 100 A AC-10.75 kW31.3 AScrewABB
MO132-4.0Manual motor starter MO132-4.0, 1.5 kW AC-3 / 4.0 100 A AC-11.5 kW50.0 AScrewABB
MO132-6.3Manual motor starter MO132-6.3, 2.2 kW AC-3 / 6.3 100 A AC-12.2 kW78.8 AScrewABB
MO132-10Manual motor starter MO132-10, 4.0 kW AC-3 / 10 100 A AC-14.0 kW125 AScrewABB
MO132-12Manual motor starter MO132-12, 5.5 kW AC-3 / 12 100 A AC-15.5 kW150 AScrewABB
MO132-16Manual motor starter MO132-16, 7.5 kW AC-3 / 16 100 A AC-17.5 kW200 AScrewABB
MO132-20Manual motor starter MO132-20, 7.5 kW AC-3 / 20 100 A AC-17.5 kW250 AScrewABB
MO132-25Manual motor starter MO132-25, 11 kW AC-3 / 25 50 A AC-111 kW313 AScrewABB
MO132-32Manual motor starter MO132-32, 15 kW AC-3 / 32 30 A AC-115 kW400 AScrewABB
MO165-20Manual motor starter MO165-20, 7.5 kW AC-3 / 20 100 A AC-17.5 kW300 AScrewABB
MO165-25Manual motor starter MO165-25, 11 kW AC-3 / 25 100 A AC-111 kW375 AScrewABB
MO165-32Manual motor starter MO165-32, 15 kW AC-3 / 32 100 A AC-115 kW480 AScrewABB
MO165-42Manual motor starter MO165-42, 22 kW AC-3 / 42 50 A AC-122 kW630 AScrewABB
MO165-54Manual motor starter MO165-54, 22 kW AC-3 / 54 30 A AC-122 kW810 AScrewABB
MO165-65Manual motor starter MO165-65, 30 kW AC-3 / 65 30 A AC-130 kW975 AScrewABB
MO165-73Manual motor starter MO165-73, 37 kW AC-3 / 73 30 A AC-137 kW1022 AScrewABB
MO165-80Manual motor starter MO165-80, 45 kW AC-3 / 80 30 A AC-145 kW1120 AScrewABB
MS116-0.4Manual motor starter MS116-0.4, 0.09 kW AC-3 / 0.25 ... 0.40 50 A AC-10.09 kW5.00 AScrewABB
MS116-0.4-HKF1-11Manual motor starter MS116-0.4-HKF1-11, 0.09 kW AC-3 / 0.25 ... 0.40 50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.09 kW5.00 AScrewABB
MS116-0.16-HKF1-11Manual motor starter MS116-0.16-HKF1-11, 0.03 (1) kW AC-3 / 0.10 ... 0.16 50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.03 (1) kW2.00 AScrewABB
MS116-0.25Manual motor starter MS116-0.25, 0.06 kW AC-3 / 0.16 ... 0.25 50 A AC-10.06 kW3.10 AScrewABB
MS116-0.25-HKF1-11Manual motor starter MS116-0.25-HKF1-11, 0.06 kW AC-3 / 0.16 ... 0.25 50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.06 kW3.10 AScrewABB
MS116-0.63Manual motor starter MS116-0.63, 0.18 kW AC-3 / 0.40 ... 0.63 50 A AC-10.18 kW7.90 AScrewABB
MS116-0.63-HKF1-11Manual motor starter MS116-0.63-HKF1-11, 0.18 kW AC-3 / 0.40 ... 0.63 50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.18 kW7.90 AScrewABB
MS116-1.0Manual motor starter MS116-1.0, 0.25 kW AC-3 / 0.63 ... 1.00 50 A AC-10.25 kW12.5 AScrewABB
MS116-1.0-HKF1-11Manual motor starter MS116-1.0-HKF1-11, 0.25 kW AC-3 / 0.63 ... 1.00 50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.25 kW12.5 AScrewABB
MS116-1.6Manual motor starter MS116-1.6, 0.55 kW AC-3 / 1.00 ... 1.60 50 A AC-10.55 kW20.0 AScrewABB
MS116-1.6-HKF1-11Manual motor starter MS116-1.6-HKF1-11, 0.55 kW AC-3 / 1.00 ... 1.60 50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.55 kW20.0 AScrewABB
MS116-2.5Manual motor starter MS116-2.5, 0.75 kW AC-3 / 1.60 ... 2.50 A AC-10.75 kW31.3 AScrewABB
MS116-2.5-HKF1-11Manual motor starter MS116-2.5-HKF1-11, 0.75 kW AC-3 / 1.60 ... 2.50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.75 kW31.3 AScrewABB
MS116-4.0Manual motor starter MS116-4.0, 1.50 kW AC-3 / 2.50 ... 4.00 50 A AC-11.50 kW50.0 AScrewABB
MS116-4.0-HKF1-11Manual motor starter MS116-4.0-HKF1-11, 1.50 kW AC-3 / 2.50 ... 4.00 50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.1.50 kW50.0 AScrewABB
MS116-6.3Manual motor starter MS116-6.3, 2.20 kW AC-3 / 4.00 ... 6.30 50 A AC-12.20 kW78.8 AScrewABB
MS116-6.3-HKF1-11Manual motor starter MS116-6.3-HKF1-11, 2.20 kW AC-3 / 4.00 ... 6.30 50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.2.20 kW78.8 AScrewABB
MS116-10Manual motor starter MS116-10, 4.00 kW AC-3 / 6.30 ... 10.0 50 A AC-14.00 kW150 AScrewABB
MS116-10.0-HKF1-11Manual motor starter MS116-10.0-HKF1-11, 4.00 kW AC-3 / 6.30 ... 10.0 50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.4.00 kW150 AScrewABB
MS116-12Manual motor starter MS116-12, 5.50 kW AC-3 / 8.00 ... 12.0 25 A AC-15.50 kW180 AScrewABB
MS116-12.0-HKF1-11Manual motor starter MS116-12.0-HKF1-11, 5.50 kW AC-3 / 8.00 ... 12.0 25 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.5.50 kW180 AScrewABB
MS116-16Manual motor starter MS116-16, 7.50 kW AC-3 / 10.0 ... 16.0 16 A AC-17.50 kW240 AScrewABB
MS116-16.0-HKF1-11Manual motor starter MS116-16.0-HKF1-11, 7.50 kW AC-3 / 10.0 ... 16.0 16 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.7.50 kW240 AScrewABB
MS116-20Manual motor starter MS116-20, 7.50 kW AC-3 / 16.0 ... 20.0 10 A AC-17.50 kW300 AScrewABB
MS116-20-HKF1-11Manual motor starter MS116-20-HKF1-11, 7.50 kW AC-3 / 16.0 ... 20.0 10 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.7.50 kW300 AScrewABB
MS116-25Manual motor starter MS116-25, 11.0 kW AC-3 / 20.0 ... 25.0 10 A AC-111.0 kW375 AScrewABB
MS116-25-HKF1-11Manual motor starter MS116-25-HKF1-11, 11.0 kW AC-3 / 20.0 ... 25.0 10 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.11.0 kW375 AScrewABB
MS116-32Manual motor starter MS116-32, 15.0 kW AC-3 / 25.0 ... 32.0 10 A AC-115.0 kW480 AScrewABB
MS116-32-HKF1-11Manual motor starter MS116-32-HKF1-11, 15.0 kW AC-3 / 25.0 ... 32.0 10 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.15.0 kW480 AScrewABB
MS132-0.4Manual motor starter MS132-0.4, 0.09 kW AC-3 / 0.25 … 0.40 100 A AC-10.09 kW5.00 AScrewABB
MS132-0.4-HKF1-11Manual motor starter MS132-0.4-HKF1-11, 0.09 kW AC-3 / 0.25 ... 0.40 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.09 kW5.0 AScrewABB
MS132-0.4KManual motor starter MS132-0.4K, 0.09 kW AC-3 / 0.25 … 0.40 100 A AC-10.09 kW5.00 APush-in SpringABB
MS132-0.16-HKF1-11Manual motor starter MS132-0.16-HKF1-11, 0.03 (1) kW AC-3 / 0.10 ... 0.16 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.03 (1) kW2.00 AScrewABB
MS132-0.25Manual motor starter MS132-0.25, 0.06 kW AC-3 / 0.16 … 0.25 100 A AC-10.06 kW3.10 AScrewABB
MS132-0.25-HKF1-11Manual motor starter MS132-0.25-HKF1-11, 0.06 kW AC-3 / 0.16 ... 0.25 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.06 kW3.10 AScrewABB
MS132-0.25KManual motor starter MS132-0.25K, 0.06 kW AC-3 / 0.16 … 0.25 100 A AC-10.06 kW3.10 APush-in SpringABB
MS132-0.63Manual motor starter MS132-0.63, 0.18 kW AC-3 / 0.40 … 0.63 100 A AC-10.18 kW7.90 AScrewABB
MS132-0.63-HKF1-11Manual motor starter MS132-0.63-HKF1-11, 0.18 kW AC-3 / 0.40 ... 0.63 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.18 kW7.90 AScrewABB
MS132-0.63KManual motor starter MS132-0.63K, 0.18 kW AC-3 / 0.40 … 0.63 100 A AC-10.18 kW7.90 APush-in SpringABB
MS132-0.63KTManual motor starter MS132-0.63KT, setting range 0.40…0.63 A———ABB
MS132-0.63TManual motor starter MS132-0.63T, setting range 0.40…0.63 A———ABB
MS132-1.0Manual motor starter MS132-1.0, 0.25 kW AC-3 / 0.63 … 1.00 100 A AC-10.25 kW12.5 AScrewABB
MS132-1.0-HKF1-11Manual motor starter MS132-1.0-HKF1-11, 0.25 kW AC-3 / 0.63 ... 1.00 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.25 kW12.5 AScrewABB
MS132-1.0KManual motor starter MS132-1.0K, 0.25 kW AC-3 / 0.63 … 1.00 100 A AC-10.25 kW12.5 APush-in SpringABB
MS132-1.0KTManual motor starter MS132-1.0KT, setting range 0.63…1.00 A———ABB
MS132-1.0TManual motor starter MS132-1.0T, setting range 0.63…1.00 A———ABB
MS132-1.6Manual motor starter MS132-1.6, 0.55 kW AC-3 / 1.00 … 1.60 100 A AC-10.55 kW20.0 AScrewABB
MS132-1.6-HKF1-11Manual motor starter MS132-1.6-HKF1-11, 0.55 kW AC-3 / 1.00 ... 1.60 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.55 kW20.0 AScrewABB
MS132-1.6KManual motor starter MS132-1.6K, 0.55 kW AC-3 / 1.00 … 1.60 100 A AC-10.55 kW20.0 APush-in SpringABB
MS132-1.6KTManual motor starter MS132-1.6KT, setting range 1.00…1.60 A———ABB
MS132-1.6TManual motor starter MS132-1.6T, setting range 1.00…1.60 A———ABB
MS132-2.5Manual motor starter MS132-2.5, 0.75 kW AC-3 / 1.60 … 2.50 100 A AC-10.75 kW31.3 AScrewABB
MS132-2.5-HKF1-11Manual motor starter MS132-2.5-HKF1-11, 0.75 kW AC-3 / 1.60 ... 2.50 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.0.75 kW31.3 AScrewABB
MS132-2.5KManual motor starter MS132-2.5K, 0.75 kW AC-3 / 1.60 … 2.50 100 A AC-10.75 kW31.3 APush-in SpringABB
MS132-2.5KTManual motor starter MS132-2.5KT, setting range 1.60…2.50 A———ABB
MS132-2.5TManual motor starter MS132-2.5T, setting range 1.60…2.50 A———ABB
MS132-4.0Manual motor starter MS132-4.0, 1.50 kW AC-3 / 2.50 … 4.00 100 A AC-11.50 kW50.0 AScrewABB
MS132-4.0-HKF1-11Manual motor starter MS132-4.0-HKF1-11, 1.50 kW AC-3 / 2.50 ... 4.00 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.1.50 kW50.0 AScrewABB
MS132-4.0KManual motor starter MS132-4.0K, 1.50 kW AC-3 / 2.50 … 4.00 100 A AC-11.50 kW50.0 APush-in SpringABB
MS132-4.0KTManual motor starter MS132-4.0KT, setting range 2.50…4.00 A———ABB
MS132-4.0TManual motor starter MS132-4.0T, setting range 2.50…4.00 A———ABB
MS132-6.3Manual motor starter MS132-6.3, 2.20 kW AC-3 / 4.00 … 6.30 100 A AC-12.20 kW78.8 AScrewABB
MS132-6.3-HKF1-11Manual motor starter MS132-6.3-HKF1-11, 2.20 kW AC-3 / 4.00 ... 6.30 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.2.20 kW78.8 AScrewABB
MS132-6.3KManual motor starter MS132-6.3K, 2.20 kW AC-3 / 4.00 … 6.30 100 A AC-12.20 kW78.8 APush-in SpringABB
MS132-6.3KTManual motor starter MS132-6.3KT, setting range 4.00…6.30 A———ABB
MS132-6.3TManual motor starter MS132-6.3T, setting range 4.00…6.30 A———ABB
MS132-10Manual motor starter MS132-10, 4.00 kW AC-3 / 6.30 … 10.0 100 A AC-14.00 kW150 AScrewABB
MS132-10.0-HKF1-11Manual motor starter MS132-10.0-HKF1-11, 4.00 kW AC-3 / 6.30 ... 10.0 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.4.00 kW150 AScrewABB
MS132-10KManual motor starter MS132-10K, 4.00 kW AC-3 / 6.30 … 10.0 100 A AC-14.00 kW150 APush-in SpringABB
MS132-10KTManual motor starter MS132-10KT, setting range 6.30…10.0 A———ABB
MS132-10TManual motor starter MS132-10T, setting range 6.30…10.0 A———ABB
MS132-12Manual motor starter MS132-12, 5.50 kW AC-3 / 8.00 … 12.0 100 A AC-15.50 kW180 AScrewABB
MS132-12.0-HKF1-11Manual motor starter MS132-12.0-HKF1-11, 5.50 kW AC-3 / 8.00 ... 12.0 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.5.50 kW180 AScrewABB
MS132-12TManual motor starter MS132-12T, setting range 8.00…12.0 A———ABB
MS132-16Manual motor starter MS132-16, 7.50 kW AC-3 / 10.0 … 16.0 100 A AC-17.50 kW240 AScrewABB
MS132-16-HKF1-20Manual motor starter MS132-16-HKF1-20, 7.50 kW AC-3 / 10 ... 16 100 A AC-1, mounted auxiliary contacts 2 n.o. + 0 n.c.7.50 kW240 AScrewABB
MS132-16.0-HKF1-11Manual motor starter MS132-16.0-HKF1-11, 7.50 kW AC-3 / 10.0 ... 16.0 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.7.50 kW240 AScrewABB
MS132-16KManual motor starter MS132-16K, 7.50 kW AC-3 / 10.0 … 16.0 100 A AC-17.50 kW240 APush-in SpringABB
MS132-16KTManual motor starter MS132-16KT, setting range 10.0…16.0 A———ABB
MS132-16TManual motor starter MS132-16T, setting range 10.0…16.0 A———ABB
MS132-20Manual motor starter MS132-20, 7.50 kW AC-3 / 16.0 … 20.0 100 A AC-17.50 kW300 AScrewABB
MS132-20-HKF1-11Manual motor starter MS132-20-HKF1-11, 7.50 kW AC-3 / 16.0 ... 20.0 100 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.7.50 kW300 AScrewABB
MS132-20KManual motor starter MS132-20K, 7.50 kW AC-3 / 16.0 … 20.0 100 A AC-17.50 kW300 APush-in SpringABB
MS132-20KTManual motor starter MS132-20KT, setting range 16.0…20.0 A———ABB
MS132-20TManual motor starter MS132-20T, setting range 16.0…20.0 A———ABB
MS132-25Manual motor starter MS132-25, 11.0 kW AC-3 / 20.0 … 25.0 50 A AC-111.0 kW375 AScrewABB
MS132-25-HKF1-11Manual motor starter MS132-25-HKF1-11, 11.0 kW AC-3 / 20.0 ... 25.0 50 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.11.0 kW375 AScrewABB
MS132-25KManual motor starter MS132-25K, 11.0 kW AC-3 / 20.0 … 25.0 50 A AC-111.0 kW375 APush-in SpringABB
MS132-25KTManual motor starter MS132-25KT, setting range 20.0…25.0 A———ABB
MS132-25TManual motor starter MS132-25T, setting range 20.0…25.0 A———ABB
MS132-32Manual motor starter MS132-32, 15.0 kW AC-3 / 25.0 … 32.0 30 A AC-115.0 kW480 AScrewABB
MS132-32-HKF1-11Manual motor starter MS132-32-HKF1-11, 15.0 kW AC-3 / 25.0 ... 32.0 30 A AC-1, mounted auxiliary contacts 1 n.o. + 1 n.c.15.0 kW480 AScrewABB
MS132-32KManual motor starter MS132-32K, 15.0 kW AC-3 / 25.0 … 32.0 25 A AC-115.0 kW480 APush-in SpringABB
MS165-20Manual motor starter MS165-20, 7.5 kW AC-3 / 14 ... 20 100 A AC-17.5 kW300 AScrewABB
MS165-25Manual motor starter MS165-25, 11 kW AC-3 / 18 ... 25 100 A AC-111 kW375 AScrewABB
MS165-32Manual motor starter MS165-32, 15 kW AC-3 / 23 ... 32 100 A AC-115 kW480 AScrewABB
MS165-42Manual motor starter MS165-42, 22 kW AC-3 / 30 ... 42 50 A AC-122 kW630 AScrewABB
MS165-54Manual motor starter MS165-54, 22 kW AC-3 / 40 ... 54 30 A AC-122 kW810 AScrewABB
MS165-65Manual motor starter MS165-65, 30 kW AC-3 / 52 ... 65 30 A AC-130 kW975 AScrewABB
MS165-73Manual motor starter MS165-73, 37 kW AC-3 / 62 ... 73 30 A AC-137 kW1022 AScrewABB
MS165-80Manual motor starter MS165-80, 45 kW AC-3 / 70 ... 80 30 A AC-145 kW1120 AScrewABB
Magnetic Switch(MS)Features Provides motor protection solution applicable for various industrial systems with enhanced durability and insulation performance Decreased installing s———Hyundai Electric