Motor control
Soft starters supplier in Saudi Arabia
Soft starters ramp motor voltage up and down to cut starting current, mechanical shock and water hammer, at a lower price than a drive when speed control is not needed.
Compact soft starters
Small units for pumps, fans and compressors, often with internal bypass and simple settings.
- Schneider Electric Soft STARTER-ATS22-CONTROL 220 V-POWER 230 V(18.5 kW)/400...440V(37 kW)/500 V(45 kW) ATS22D75S6
- Schneider Electric Soft starter, ATS22 control, 220 V-POWER 230 V, 3 phase, 75 kW, 88 A, 50/60 Hz ATS22D88Q
- Siemens 3RW30 400 V AC 15 kW 3-phase soft starter 3RW3013-1BB04
- Siemens 3RW30 480 V AC 3 kW 3-phase soft starter 3RW3014-1BB04
- Siemens 3RW30 480 V 3 kW 3-phase soft starter IP20 3RW3014-1BB14
- Siemens 3RW30 400 V AC 4 kW 3-phase soft starter 3RW3016-1BB14
- Siemens 3RW30 400 V AC 75 kW 3-phase soft starter 3RW3018-1BB04
- Siemens 3RW30 400 V AC 11 kW 3-phase soft starter 3RW3026-1BB04
Advanced and heavy-duty soft starters
Torque control, pump cleaning, motor protection and communication for large and critical motors.
- Schneider Electric Soft starter for asynchronous motor, altistart 22, control 230 V, 230 to 440 V ATS22C17Q
- Schneider Electric Soft starter for asynchronous motor, altistart 22, control 230 V, 230-440 V ATS22C41Q
- Schneider Electric Soft starter for asynchronous motor, ATS48, 14.8 A, 230..415V, 3..15 kW ATS48D17Q
- Schneider Electric Soft starter for asynchronous motor, ATS48, 69 a, 230..415 v, 15..55 kW ATS48D75Q
- Schneider Electric Remote terminal, ATS48, for soft starter for asynchronous motor VW3G48101
- Siemens 3RW52 480 V AC 11 kW 3-phase soft starter 3RW5213-1AC04
- Siemens 3RW52 480 V AC 15 kW 3-phase soft starter 3RW5214-1AC04
- Siemens 3RW52 480 V AC 185 kW 3-phase soft starter 3RW5215-1AC04
Other soft starters
Other makes by motor current and starts per hour.
How to choose a soft starter
Motor current and starts per hour
Size by full-load current and how often the motor starts; frequent starts or long ramps need a larger unit.
Inline or inside-delta
Inside-delta wiring lets a smaller starter run a larger motor; check the motor has six terminals.
Soft starter or VFD
If the process needs speed control or energy saving at part load, choose a VFD; for a smooth start only, a soft starter is cheaper.
Questions
Do soft starters need a bypass contactor?
Many current models have the bypass built in. Older or larger units may need an external bypass contactor, which we can quote with it.
Can you supply a replacement for an old soft starter?
Yes. Send the nameplate and the motor data; we offer the successor model or an equivalent with the same current and wiring.
Do you deliver soft starters outside Jeddah?
Yes. We supply from Jeddah to Riyadh, Dammam and Al Khobar, Jubail, Yanbu, Makkah and every other region; the delivery time is on the quotation.