Hazardous area lighting · Oil, gas and petrochemical
Eaton Crouse-Hinds Champ VMVL LED Hazardous-Area Luminaires
The Champ VMVL is the compact LED luminaire from Eaton Crouse-Hinds for Zone 2, Zone 21 and Class I Div 2 areas. Six sizes replace 70 W to 400 W HID fittings with up to 127 lm/W, a universal driver and a sealed IP66 housing that works from -40 °C to +65 °C. It fits existing Champ mounting modules, so an HID-to-LED upgrade is a head swap.
Also searched as: VMVL, VMV LED, Champ VMV LED, Crouse-Hinds VMVL3 / VMVL5 / VMVL7 / VMVL9 / VMVL11 / VMVL13, Eaton explosion-proof LED light, Zone 2 LED luminaire.




Six sizes
| Model | Lumens (UNV1) | Watts (UNV1) | lm/W | Replaces HID | Weight | UNV34 (347-480 V) |
|---|---|---|---|---|---|---|
| VMVL-3 | 3,302 lm | 27 W | 122 | 70 W | 8.62 kg | 3,250 lm · 28 W |
| VMVL-5 | 5,412 lm | 43 W | 126 | 100 W | 8.62 kg | 5,537 lm · 44 W |
| VMVL-7 | 7,327 lm | 57 W | 129 | 175 W | 8.62 kg | 7,442 lm · 57 W |
| VMVL-9 | 9,229 lm | 75 W | 123 | 250 W | 8.70 kg | 9,234 lm · 68 W |
| VMVL-11 | 11,266 lm | 92 W | 122 | 320 W | 8.70 kg | 11,114 lm · 83 W |
| VMVL-13 | 13,582 lm | 92 W | 147 | 400 W | 8.70 kg | 13,582 lm · 91 W |
Nominal lumens; UNV1 = 100-277 VAC / 127-250 VDC, UNV34 = 347-480 VAC. Mounting module weight is extra. Up to 77% energy saving against HID fittings.
Where it is used
- Refineries, gas plants and petrochemical process units
- Offshore platforms, drilling rigs and marine areas
- Loading racks, tank farms and pump stations
- Compressor houses, tunnels and walkways
- Wastewater, grain and dust (Zone 21 / Class II) areas
How to order
- Pick the size by the light you need or the HID lamp it replaces (table above).
- Pick the mounting module and conduit size (3/4", 1", 20 mm or 25 mm).
- Pick the optic (Type I, III or V), colour temperature and voltage (UNV1 or UNV34).
- Add options: guard, safety cable, diffused or uplight lens, redundant driver, photocell.
- Send us the list or the existing catalogue numbers; we confirm the full catalogue number, certificates and delivery with the quotation.
Technical specifications (all sizes)
| Property | Value |
|---|---|
| Certifications | Class I Div 2 Groups A, B, C, D; Class I Zone 2 AEx ec mb IIC; Class II Groups E, F, G; Class III; Zone 21 tb IIIC; UL / cUL listed; IEC / ATEX (100-277 VAC / 127-250 VDC) |
| Ex marking | II 3 G Ex ec mb IIC T5/T4 Gc · II 2 D Ex tb IIIC T72-T92 °C Db · IECEx UL 13.0052X |
| Voltage | UNV1: 100-277 VAC 50/60 Hz and 127-250 VDC · UNV34: 347-480 VAC · IEC: 100-240 VAC |
| Driver | 0-10 V dimmable; power factor ≥ 0.90; THD ≤ 15%; redundant driver option S892 (VMVL-7 to -13) |
| Protection | IP66, Type 4X, wet locations |
| Ambient | -40 °C to +65 °C |
| Rated life | Up to 60,000 h at 55 °C |
| Light colour | 5000K 70 CRI standard; 4000K 70 CRI or 3000K 80 CRI option; amber and green LEDs available |
| Optics | Type I, Type III and Type V |
| Construction | Die-cast aluminium with epoxy powder coat; glass lens; silicone gaskets; stainless steel hardware; factory sealed, no external seals needed |
| Standards | UL 844, UL 1598, UL 1598A (marine), CSA C22.2 No. 137, IEC/EN 60079-0, -7, -18, -31, IEC/EN 60529, IEC/EN 60598 |
Champ VMVL Intelligent: app-controlled lighting
The intelligent version adds Bluetooth Low Energy control from a phone app and an optional integral multi-sensor, so lights run only when and where they are needed. Control can cut lighting energy by up to 50% on top of the LED saving.
- Live fixture ID, wireless on/off and dimming, high-end trim
- Grouping, scheduling, occupancy sensing and daylight harvesting (advanced plan)
- Integral multi-sensor: PIR occupancy with LED indicator and photo sensor for lux reporting, no field wiring
- Fixture-to-fixture range up to about 9 m (30 ft); health and temperature monitoring with alarms
- Class I Div 2, Class I Zone 2 Ex ec ia IIC, Zone 21, Type 4X / IP66; DEMKO 19 ATEX 2118X
- 7-year fixture warranty, 10 years with an active advanced service plan
- 5.45 kg luminaire, 100-277 VAC 50/60 Hz and 127-250 VDC
| Model | Lumens | Watts | lm/W |
|---|---|---|---|
| VMVL-3-UNV1 | 3,225 lm | 21 W | 153 |
| VMVL-5-UNV1 | 5,456 lm | 35 W | 155 |
| VMVL-7-UNV1 | 7,607 lm | 50 W | 152 |
| VMVL-AT-UNV1 (amber) | 2,030 lm | 27 W | 75 |
| VMVL-GT-UNV1 (green) | 2,900 lm | 20 W | 145 |
Mounting modules
Choose the mounting module for the site: pendant, cone pendant, ceiling, wall or stanchion. Existing Champ modules can be reused when upgrading from HID.
Accessories and spare drivers
- VMVL S831 K1 · Safety cable kit
- VMVL S890 K1 · Quick Clip kit
- VMVL S812 K1 DBR · Trunnion mount kit
- P3001 · Wire lens guard
- D2S20 · Photocell 120 V
- D2S208 277 · Photocell 208-277 V
- CHMM1 · Mounting adapter (retrofit)
- CHMM2 · Mounting adapter (retrofit)
- VMVL-3-5-7L-UNV1-DRIVER KIT · Spare driver VMVL-3/5/7, 100-277 VAC
- VMVL-9-11L-UNV1-DRIVER KIT · Spare driver VMVL-9/11, 100-277 VAC
- VMVL-96W-13L-UNV1-M2-DRIVER-REPL-KIT · Spare driver VMVL-13, 100-277 VAC
- VMVL-13-M2-DRIVER-KIT · Spare driver VMVL-13, 347-480 VAC
Questions buyers ask
What does Champ VMVL replace?
The six sizes replace 70 W (VMVL-3), 100 W (VMVL-5), 175 W (VMVL-7), 250 W (VMVL-9), 320 W (VMVL-11) and 400 W (VMVL-13) HID fittings, using about 28 W to 95 W.
Can it go in Zone 1?
No. The VMVL is certified for Zone 2 / Class I Div 2 gas areas and Zone 21 / Class II dust areas. For Zone 1 ask us for a flameproof (Ex d) luminaire.
Can I reuse my existing Champ mountings?
Yes. The VMVL fits the Champ mounting modules (APM, BPM, CM, TWM, JM series), so you can change the head and keep the module and wiring.
Which voltages are available?
UNV1 covers 100-277 VAC 50/60 Hz and 127-250 VDC; UNV34 covers 347-480 VAC. The IEC / ATEX version is for 100-240 VAC.
Do you supply spare drivers?
Yes. Driver kits for each size and voltage, including the redundant (S892) versions, are listed below with their catalogue numbers.