Marechal Plugs and Sockets: DECONTACTOR, High-Current and Ex

Every Marechal range in one place: DECONTACTOR switch-rated plugs and sockets from 20 A to 250 A, single-pole connectors up to 1250 A, multicontact connectors for control circuits, explosion-proof DXN, DX and SPeX ranges for Zone 1/21 and 2/22, and the boxes, handles and glands each one needs. Pick the range below, open its datasheet, or send us your Marechal references for a quotation.

Choose the range by current

CurrentStandard / non-switchedSwitch-rated DECONTACTORHazardous area (Ex)
16-20 APNCDSN1EVO40PNCXDXN1
30-32 APNPNHTDS1DSN3DXN3
50-63 AFCDS3DSN6DS7C3DX6DXN6
90-150 ADSHTDS7C6DS6DS9DSDX9
200-400 ADS2DS4DSP400DS2DX2
500-1250 ACS1000P66SP–SPeX
Control (7-37 contacts)PN7CPN12CDN9CDN20CDSN12CDSN24CDSN37CPXN12CDXN25CDXN37C

Switch-rated (DECONTACTOR) ranges can be connected and disconnected under load; non-switched high-current ranges use pilot contacts or an upstream switch.

All Marechal ranges

Reading a Marechal reference

  • A reference is a 7-digit code (for example 3194013): the first digits give the range and housing, the next digit tells socket-outlet (4) from inlet (8), and the last digits give voltage and poles. Socket-outlets and inlets come in matching pairs that differ in that one digit.
  • Black housing: on ranges marked for it, replace the second character of the reference with 5.
  • Options are added after the reference: + 843 padlocking pin, + 453 larger release button, + R self-returning lid, + 262 / + 264 / + 976 or + 972 auxiliary contacts.
  • Regional versions of high-current single-pole connectors end in P80 (USA), P67 (Australia / New Zealand) or P40 (UK / South Africa). Zone 2/22 versions of Ex ranges carry an MZ2 ending.
  • Every socket-outlet or inlet needs a wall box, a sleeve, a handle or a spacer so its closing mechanism works; order them with the device.

Questions buyers ask

What is a DECONTACTOR?

A Marechal plug and socket with a built-in load-break switch. The circuit is only live when the plug is fully in and switched on, so it can be connected and pulled under load without arcing at the contacts.

Do you supply Marechal for hazardous areas?

Yes: DXN1, DXN3 and DXN6 (Zone 1/21 and Zone 2/22 versions), DX1 to DX2 metal DECONTACTORs up to 200 A, SPeX single-pole connectors and PXN12C, DXN25C and DXN37C multicontact connectors, with Ex boxes and cable glands.

I only have an old Marechal reference. Can you quote it?

Yes. Send the reference or a photo of the nameplate; we match it to the current catalogue reference, its mating part and the box, sleeve or handle it needs.

Which Marechal range for 63 A?

DSN6 (GRP or metal) is the 63 A switch-rated range; DS3 covers 50 A; for hazardous areas use DXN6 or DX6.

Do you provide datasheets?

Yes. Each range on this page has a Six Winds datasheet (PDF) with ratings and references, and every part number has its own page.