العربيةGet a quote

Ex plugs, receptacles and interlocked switches

Marechal 4347001

SPeX Ex single-pole inclined socket-outlet, 680 A, 1000 V, L1, red (Australia and New Zealand), without lug, IP65/IP66

High-current SPeX single-pole Ex socket-outlet for the L1 conductor, colour-coded and mechanically keyed so poles cannot be mixed up, for temporary or permanent power links in Zone 1/21 areas. Order the crimp lug, lever mechanism and the matching SPeX plug separately.

Request a quotation

Datasheet (PDF)Send on WhatsApp

Need a cross-reference?Send the part number or a nameplate photo and we confirm an approved equivalent and availability.Ask about this part
  • Genuine partsor approved equivalents on request
  • Quotation on requestone offer for mixed lists
  • Saudi company, Jeddahdelivery to sites across the Kingdom
  • Documents on requestdatasheets, certificates of origin, SABER
Marechal 4347001 — SPeX Ex single-pole inclined socket-outlet, 680 A, 1000 V, L1, red (Australia and New Zealand), without lug, IP65/IP66

Representative image. The supplied item may look different; ask us for the datasheet.

Specifications

CategoryHazardous area (Ex) equipment
Product groupEx plugs, receptacles and interlocked switches
RangeSPeX
Rated currentUp to 680 A (depends on temperature class and cable size)
Max. voltage1000 V AC / 1000 V DC
Poles1 pole + pilot
Ex markingII 2 G D Ex e IIC Gb / Ex tb IIIC Db
CertificatesIECEx LCI 12.0005X / LCIE 07 ATEX 6073 X
Zones1, 2, 21, 22
Gas groupIIC
Dust groupIIIC
Temperature classT5 / T56 °C or T6 / T56 °C at -20 °C ≤ Ta ≤ +40 °C; T5 / T76 °C at -20 °C ≤ Ta ≤ +60 °C (depends on current and cable size)
Current by cable sizefirst value T5/T56 °C at Ta ≤ +40 °C, second value T6/T56 °C at Ta ≤ +40 °C or T5/T76 °C at Ta ≤ +60 °C: 70 mm² 290/235 A; 95 mm² 415/335 A; 120 mm² 456/376 A; 150 mm² 493/415 A; 185 mm² 530/450 A; 240 mm² 570/497 A; 300 mm² 620/540 A; 400 mm² 680/600 A
Type of protectione, tb
Ambient temperature-20 °C to +60 °C
BodyGRP
Degree of protectionIP65 / IP66 (IP2X socket with cap removed)
ImpactIK08
Pilot circuitPre-wired, 6 A/250 V (pilot wiring mandatory to make and break on load)
Number of operations2000
Short-circuit current20 kA for 250 ms
StandardsIEC/EN 60079-0, 60079-7, 60079-31
Other certificationsEAC (TR CU), cCSAus, Bureau Veritas Marine
KeyingMechanical keying and colour coding for L1, L2, L3, N, E, + and -
Order separatelyLever mechanism 454A876, draw base 454A396, lugs, padlock lock 454A843
Contact wiringCrimped lug (lug not included)
TypeInclined socket-outlet (female), without lug
ConductorL1
Colour codeRed (Australia and New Zealand)
MarketAustralia and New Zealand
Matching partPlug 434100132P / 434100140P / 434100150P / 434100163P
OptionsUK, South Africa and India versions: replace the first two digits with 44

Datasheet, stock and lead time on request. If this part is discontinued or on long lead time we offer an approved equivalent.