العربية Get a quote

Technical guides

Champ VMVL catalogue number guide: size, colour, mounting, optic, guard, voltage, options and lens

A Champ VMVL catalogue number is a chain of up to nine codes in a fixed order, plus an -M2 suffix on the size 13. Each code selects one feature, a blank position means the standard choice, and some combinations are not allowed. Getting the number right first time stops a luminaire arriving with the wrong mounting, optic or driver.

By the Six Winds engineering team · Updated

Quick answer

Write VMVL, then the size (3, 5, 7, 9, 11, 13, A or G), the colour (blank 5000K, N 4000K, W 3000K), the mounting (for example 2A for a ¾ in pendant; blank for no module), the optic (blank for Type V, or R1, R3 and the ceiling variants), G for a wire guard, UNV1 or UNV34, any options (S812, S831, S890, S892, SG1, TB6) and the lens (blank clear glass, S891, S903 or UPLT). Add -M2 at the end for size 13. Blank codes are simply left out.

Step by step

  1. Start with the sizeChoose 3, 5, 7, 9, 11 or 13 by light output, or A (amber) or G (green) for coloured light. If you chose 13, remember the -M2 suffix at the end.
  2. Add the colour temperatureLeave it blank for 5000K cool white, add W for 3000K warm white, or N for 4000K neutral white on sizes 9, 11 and 13. Amber and green take no colour code.
  3. Add the mountingPick the module and hub size: pendant, cone pendant, flexible pendant, ceiling, wall or stanchion. Leave it blank when the luminaire goes onto an existing Champ module.
  4. Add the optic and guardBlank gives Type V. R1 and R3 work on every mount except ceiling; R1A, R1B, R3A1, R3A2, R3B1 and R3B2 are the ceiling versions, set by the conduit direction. Add G for a wire guard.
  5. Add the voltageUNV1 for 100-277 VAC and 127-250 VDC, UNV34 for 347-480 VAC. This position is never blank.
  6. Add options and lensOptions come next (S812, S831, S890, S892, SG1, TB6), then the lens code (S891, S903 or UPLT). Clear glass needs no code.
  7. Check the restrictionsGo through the rules list below before you send the number, or build it in our catalogue number builder, which applies the rules for you.

The order of the codes

Every VMVL number follows the same pattern: VMVL-[size]-[colour]-[mounting]-[optic]-[guard]-[voltage]-[options]-[lens], with -M2 added at the very end for size 13. When a position takes its standard choice it is not written at all, so a number can be short or long.

PositionCode groupLeft blank meansExample
1Seriesalways VMVLVMVL
2Size (light output)never blank3
3Colour temperature5000K cool whiteW
4Mountingno mounting module2A
5OpticType VR1
6Lens guardno guardG
7Voltagenever blankUNV1
8Accessories and optionsnoneS831
9Lens materialclear glassS891
End-M2 suffixonly for size 13-M2

Size and colour codes

Size codeNominal light output (ordering table)
33,250 lm
55,537 lm
77,442 lm
99,234 lm
1111,114 lm
1313,100 lm (add -M2 at the end)
AAmber, 5,200 lm
GGreen, 4,300 lm
Colour codeColour temperatureNote
blank5000K, CRI 70 (cool white)standard
N4000K, CRI 70 (neutral white)sizes 9, 11 and 13 only; confirm availability with us
W3000K, CRI 80 (warm white)

The ordering table rounds the nominal lumens; the electrical tables give 3,302 to 13,582 lm depending on size and driver. Colour codes do not apply to the amber and green versions. The maker also states that 5700K and 6500K can be made on request.

Mounting codes

CodeMountingCodeMounting
blankNo mounting module2HA¾ in flexible pendant
J1-½ in stanchion, 25° angled2C¾ in ceiling
P1-½ in stanchion, straight3C1 in ceiling
2A¾ in pendant20C20 mm ceiling
3A1 in pendant25C25 mm ceiling
20A20 mm pendant2TW¾ in wall
25A25 mm pendant3TW1 in wall
2B¾ in cone pendant20TW20 mm wall
3B1 in cone pendant25TW25 mm wall

The size in each code is the hub size of the mounting module; match it to the conduit on site. Blank means the luminaire is supplied without a module, the usual choice when it goes onto an existing Champ HID or LED module. For another make's mount, order a CHMM1 to CHMM4 adapter separately.

Optic and lens guard codes

Optic codeLight patternUse with
blankType V (standard), round patternall mounts
R1Type Iall mounts except ceiling
R1AType I, conduit 45° anticlockwise from the top-hat hingeceiling modules only
R1BType I, conduit 135° clockwise from the top-hat hingeceiling modules only
R3Type IIIall mounts except ceiling
R3APType III, for an Appleton top-hat adapter used with the Champ fixturemarked for ceiling modules in the ordering table, drawn as a Type III wall pattern; confirm with us
R3A1Type III, conduit 45° anticlockwise from the top-hat hingeceiling modules only
R3A2Type III, conduit 135° clockwise from the top-hat hingeceiling modules only
R3B1Type III, conduit 45° clockwise from the top-hat hingeceiling modules only
R3B2Type III, conduit 135° anticlockwise from the top-hat hingeceiling modules only
Guard codeMeaning
blankNo guard
GWire guard

On ceiling modules the Type I and Type III patterns are fixed relative to the conduit entry, which is why the ceiling optics come in versions for 45° and 135°, clockwise or anticlockwise from the top-hat hinge. Look at the conduit direction on site before choosing. A separate wire guard (PA3001) and an UPLT wire guard (P3003) can also be ordered as spares.

Voltage, options and lens codes

Voltage codeSupply
UNV1100-277 VAC, 50/60 Hz and 127-250 VDC (IEC voltage 100-240 VAC, 50/60 Hz)
UNV34347-480 VAC, 50/60 Hz
Option codeMeaningRestriction
S812Trunnion mount kit with pinceiling mount only
S831Safety cable
S890Quick clip
S892Redundant driverVMVL-7, 9, 11 and 13 only
SG1Enhanced surge rating, ANSI compliantnot on 11, 13 or any UNV34 model
TB6Six-pole terminal blockNEC/CEC only
Lens codeLensRestriction
blankClear glassstandard
S891Diffused glass
S903Polycarbonate
UPLTUplight refractor lensType V optic only

Options can be ordered with the luminaire or separately. The separate kits are VMVL S812 K1 (trunnion mount kit with pin), VMVL S812 K1 DBR (PVC-coated trunnion kit), VMVL S831 K1 (safety cable) and VMVL S890 K1 (quick clip); photocells D2S20 (120 V) and D2S208 277 (208-277 V) are also listed. Replacement driver kits for every size and voltage are on the Champ VMVL range page.

Rules and restrictions

  • Size 13: add -M2 at the end of the number.
  • Colour N (4000K): sizes 9, 11 and 13 only. No colour code on amber (A) or green (G).
  • R1 and R3: any mount except ceiling. R1A, R1B, R3A1, R3A2, R3B1, R3B2: ceiling modules only.
  • S812 trunnion: ceiling mount only.
  • S892 redundant driver: VMVL-7, 9, 11 and 13 only.
  • SG1 surge option: not on sizes 11 and 13, and not on any UNV34 model.
  • TB6 six-pole terminal block: NEC/CEC installations only.
  • UPLT uplight refractor lens: Type V optic only (blank optic code).

Common mistakes: VMVL-5-N (neutral white on a size 5), VMVL-9-2A-R1A (a ceiling optic on a pendant), VMVL-7-2A-R1-UNV1-UPLT (uplight lens with a Type I optic) and a size 13 number without -M2.

Worked examples

Catalogue numberWhat it describes
VMVL-3-W-2A-R1-G-UNV1-S831-S891The maker's own example: size 3, 3000K warm white, ¾ in pendant, Type I optic, wire guard, UNV1 driver, safety cable, diffused glass lens.
VMVL-13-2A-R1-UNV1-S831-M2The maker's size 13 example: 5000K (blank), ¾ in pendant, Type I, no guard, UNV1, safety cable, clear glass (blank), with the -M2 suffix.
VMVL-9-N-2C-R3A1-G-UNV1-S831Size 9, 4000K neutral white (allowed on 9 to 13), ¾ in ceiling, Type III for a ceiling module with the conduit 45° anticlockwise, wire guard, UNV1, safety cable, clear glass.
VMVL-11-25A-UNV34-S892Size 11, 5000K, 25 mm pendant, Type V, no guard, 347-480 VAC driver, redundant driver, clear glass. SG1 could not be added here: it is not offered on size 11 or on UNV34.
VMVL-5-20TW-R3-G-UNV1-SG1-S903Size 5, 5000K, 20 mm wall, Type III, wire guard, UNV1, enhanced ANSI surge rating, polycarbonate lens.

Send us the number, or the choices you have made, and we check it against the rules before quoting. The VMVL catalogue number builder builds a valid number step by step.

Common questions

What does a blank code mean in a VMVL number?

It means the standard choice for that position: 5000K colour, no mounting module, Type V optic, no guard, no options or clear glass lens. Blank positions are simply left out of the number.

Why does my VMVL-13 number end in -M2?

The maker asks for the -M2 suffix at the end of every size 13 catalogue number, for example VMVL-13-2A-R1-UNV1-S831-M2.

Can I order the VMVL without a mounting module?

Yes. Leave the mounting position blank. This is the usual choice when the luminaire goes onto an existing Champ HID or LED mounting module.

What is the S892 option?

A redundant driver, offered on VMVL-7, 9, 11 and 13. It draws a few more watts; for example the VMVL-9 on UNV1 goes from 75 W to 80 W.

Do I need TB6 on an IEC project?

No. The six-pole terminal block option TB6 is listed for NEC/CEC installations only.

Need these items? E-mail your list or a nameplate photo to sales@sixwinds.com.sa, or use the RFQ form.

This guide is general information. Final selection must follow the project design, the applicable standards and the maker's data.