The right loading hose matches three things: the outlet of your pneumatic loader, the diameter and direction of the blast holes, and the depth of the holes you charge. This guide walks through each one with the sizes we hold in Jeddah.

By the Six Winds engineering team · Updated

Quick answer

Start from the loader: the hose bore should match the loader outlet and the bore the loader maker recommends. Then check the hose outside diameter passes freely into your blast holes, and order a coil length that reaches the bottom of your deepest hole with slack to handle. We hold 16, 19, 25 and 32 mm bore.

Step by step

  1. Read the loader outlet and the maker's recommendationThe loader or charging unit is built for a hose bore range; its manual or nameplate gives it. Using a larger or smaller bore changes the flow and the back-pressure.
  2. Check the blast-hole diameterThe hose outside diameter must pass freely into the hole with room for the prill and air to flow back. Compare the hole diameter with the outside diameters in the table below.
  3. Consider the hole directionDown-holes are charged by gravity and air; up-holes and steep holes need a hose that can be pushed in and stays where it is placed, which favours the smaller, firmer bores.
  4. Choose the coil lengthThe hose must reach the bottom of the deepest hole from where the loader stands, plus slack for handling. Coils are 30, 61 or 91 m depending on the bore.
  5. Count the coilsPlan spares: a loader in daily use should have a spare coil on site so charging does not stop when a hose is damaged.

Sizes we hold in Jeddah

All sizes are anti-static ANFO loading hose with a continuous orange stripe, rated for a maximum working pressure of 120 psi (0.83 MPa) and a temperature range of -35 °C to +65 °C.

Inside diameterOutside diameter (approx.)Max. working pressureWeight per 100 m (approx.)Length per coil
5/8 in · 16 mm22 mm120 psi · 0.83 MPa25 kg61 m (200 ft)
3/4 in · 19 mm27 mm120 psi · 0.83 MPa40 kg61 m (200 ft)
1 in · 25 mm34 mm120 psi · 0.83 MPa55 kg91 m (300 ft)
1-1/4 in · 32 mm41 mm120 psi · 0.83 MPa78 kg30 m (100 ft)

Matching the hose to the loader

Pneumatic loaders and charging units are designed around a hose bore. The bore sets how much prill and air the hose carries and how much back-pressure the loader works against. Take the bore from the loader manual or from the hose currently in use, not from the hole size alone. If you change the bore, confirm it with the loader maker or your blasting engineer.

Matching the hose to the blast hole

The outside diameter of the hose must pass freely into the hole and leave space around it. A hose that is a tight fit drags, wears quickly and stops air from venting back, which makes charging slow and uneven.

Compare your hole diameter with the outside diameters in the table: 22, 27, 34 and 41 mm (approx.). Your blasting engineer will set the clearance your procedure needs.

Coil length and hole depth

Coil lengths are 61 m for 16 and 19 mm bore, 91 m for 25 mm and 30 m for 32 mm. Choose a length that reaches the bottom of the deepest hole from where the loader stands, plus enough slack to handle the hose without pulling on the loader outlet. A shorter hose is lighter to handle and loses less pressure; a longer one avoids moving the loader between holes.

Weight and handling

Weights per 100 m are about 25, 40, 55 and 78 kg for the four bores. On long shifts and up-holes the smaller bores are easier on the operator; the larger bores move more product per hole.

Worked example: underground development face

A loader with a 25 mm (1 in) outlet charges 45 mm holes, up to about 4 m deep, on a development face. The loader stands about 15 m from the face.

  1. Bore: 25 mm, matching the loader outlet.
  2. Hole: the 25 mm hose has an outside diameter of about 34 mm, which passes into a 45 mm hole with room for the air to vent; the blasting engineer confirms the clearance.
  3. Length: 15 m to the face plus 4 m of hole plus slack: one 91 m coil is cut into working lengths as the site procedure allows, or kept whole on a reel.
  4. Spares: one spare coil on site.

Ordering line: "ANFO explosive loading hose, anti-static, 25 mm ID, 91 m coil, 2 coils, with test certificate and certificate of origin."

What to send us for a quotation

The loader make and model (or the bore now in use), the hole diameter, the length per coil and the number of coils, the delivery site, and the documents you need. See the ANFO explosive loading hose page or e-mail sales@sixwinds.com.sa.

Common questions

Which ANFO hose size is most common?

It depends on the loader and the holes. Small handheld and underground loaders often use 19 or 25 mm bore; larger units use bigger bores. Take the bore from your loader manual or the hose you use today.

Can I use a 32 mm hose on a 25 mm loader outlet?

Not without the loader maker's agreement. The bore changes the flow and back-pressure the loader is designed for.

What working pressure is the hose rated for?

120 psi (0.83 MPa) maximum working pressure for all four sizes we hold.

How long is each coil?

61 m (200 ft) for 16 and 19 mm, 91 m (300 ft) for 25 mm and 30 m (100 ft) for 32 mm bore.